6.5 MODULE 5 - S ERIAL C OMMUNICATIONS P ARAMETERS ( 5-SEriAL )
5-SEriAL
SEL
PARAMETER MENU
Pro
bAUd
Baud Rate
dAtA
Data Bit
PAritY
Parity Bit
Addr
Meter
Address
Abbr
Abbreviated
Printing
Prnt OPt
Print
Options
COPY
Copy Program
Settings
bAUd ?
?
9600
Prnt OPt ?
The SerialSetup Parameters are only active when one of the optional serial
communication/programming cards is installed in the meter.
Refer to the CUB5USB bulletin for details on the CUB5 USB programming
and programming requirements. This section replaces the bulletin shipped with
the RS232 and RS485 serial communications plug-in cards. Discard the
separate bulletin when using those serial plug-in cards with the CUB5B and
CUB5R.
BAUD RATE
300 1200 4800 19200
600 2400 9600 38400
Set the baud rate to match that of other serial communications equipment.
Normally, the baud rate is set to the highest value that all of the serial
communications equipment is capable of transmitting and receiving.
PRINT OPTIONS
NO YES
? NO
This parameter selects the meter values transmitted in response to a Print
Request. A print request is also referred to as a block print because more than
one parameter can be sent to a printer or computer as a block.
Selecting YES displays a sublist for choosing the meter parameters to appear
in the print block. All active parameters entered as YES in the sublist will be
transmitted during a block print. Parameters entered as NO will not be sent.
The “Print All” ( Prnt ALL ) option selects all meter values for transmitting
( YES ), without having to individually select each parameter in the sublist.
Note: Inactive parameters will not be sent regardless of the print option
setting. For example, Counter B or Scale Factor B will only be sent if Counter
B is enabled (Dual Counter mode or batch count). Likewise, the Setpoint
value(s) will not be sent unless an optional setpoint card is installed in the meter.
DATA BIT
dAtA ? 7-bit         8-bit
? 7-bit
Select either 7- or 8-bit data word length. Set the word length to match the
other serial communications equipment on the serial link.
PARITY BIT
DISPLAY
Count A
Count b
RAtE
CntA ScF
Cntb ScF
sSP1
SP2
CntA Ld
DESCRIPTION
Counter A
Counter B
Rate Value
Scale Factor A
Scale Factor B
Setpoint 1
Setpoint 2
Counter A Count Load
FACTORY
SETTING
YES
NO
NO
NO
NO
NO
NO
NO
MNEMONIC
CTA
CTB
RTE
SFA
SFB
SP1
SP2
CLD
PAritY
?
?
Odd
NO
Odd
EVEN
COPY PROGRAM SETTINGS
Addr ? to
Abbr ?
COPY ?
This parameter only appears when the Data Bit parameter is set to a 7-bit
data word length. Set the parity bit to match that of the other serial equipment
on the serial link. The meter ignores parity when receiving data and sets the
parity bit for outgoing data. If parity is set to NO , an additional stop bit is used
to force the frame size to 10 bits.
METER ADDRESS
0 99
? 00
Enter the serial node address. With a single unit, an address is not needed
and a value of zero can be used (RS232 applications). Otherwise, with multiple
bussed units, a unique address number must be assigned to each meter. The
node address applies specifically to RS485 applications.
ABBREVIATED PRINTING
NO YES
? NO
This parameter determines the formatting of data transmitted from the meter
in response to a Transmit Value command or a Block Print Request. Select NO
for a full print transmission, consisting of the meter address, mnemonics, and
parameter data. Select YES for abbreviated print transmissions, consisting of the
parameter data only. This setting is applied to all the parameters selected in the
PRINT OPTIONS. (Note: If the meter address is 0, the address will not be sent
during a full transmission.)
13
NO YES
? NO
This parameter is used to copy all the program settings from one CUB5
meter directly to another CUB5 meter, through the serial communications cards
(RS232 or RS485). The USB programming card cannot be used for the copy
procedure. No PC connection or additional software is required. Copying
program settings eliminates the need for repetitive programming when multiple
meters use identical settings.
Copy Requirements:
To copy program settings from one meter to another requires the following:
1. Both meters must have the same software version (Version 3.1 or later). The
version is displayed during the meter power-up sequence, or in Module 3 at
the Software Version Display parameter. (See Module 3 for details)
2. The meter receiving the program settings (receiver) must have the Baud Rate
set to 9600 baud. Since this is the factory default setting, a new meter will
arrive ready for copying. The meter sending the program settings (master)
should be set to the desired Baud Rate for the application (if different than
9600). This Baud Rate setting will then be copied to the receiver.
Copy Connections:
To connect the meters for copying, install a serial communications card of
the same type into each meter (RS232 or RS485). Connect the meters using the
proper cable listed in the chart.
TYPE DESCRIPTION PART NUMBER
RS232 Copy Cable RS232 10’ (RJ12-RJ12)     CBLRLC02
RS485 Copy Cable RS485 10’ (RJ12-RJ12)     CBLRLCS2
相关PDF资料
P51-50-A-J-P-5V-000-000 SENSOR 50PSI 3/8-24 UNF 1-5V
P51-15-A-J-P-5V-000-000 SENSOR 15PSI 3/8-24 UNF 1-5V
CUB5R000 COUNTER/RATE IND DUAL REFL DISPL
P51-750-A-I-P-5V-000-000 SENSOR 750PSI 7/16-20 UNF 1-5V
ASFLMPC-48.000MHZ-Z-T OSC 48.000 MHZ CMOS MEMS SMD
P51-500-A-I-P-5V-000-000 SENSOR 500PSI 7/16-20 UNF 1-5V
P51-300-A-I-P-5V-000-000 SENSOR 300PSI 7/16-20 UNF 1-5V
P51-200-A-I-P-5V-000-000 SENSOR 200PSI 7/16-20 UNF 1-5V
相关代理商/技术参数
CUB5B000 CAL D 制造商:Red Lion Controls 功能描述:CALIBRATED W/DATA - Multifunction Counter, No. of Digits / Alpha:8, Digit Height
CUB5COM1 功能描述:RS485 SERIAL COMMO CARD RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030
CUB5COM2 功能描述:RS232 SERIAL COMM CARD FOR CUB5 RoHS:是 类别:工业控制,仪表 >> 配件 系列:* 标准包装:1 系列:Aero-Motive® 130117 附件类型:拖车带 适用于相关产品:标准盒式跟踪系统 其它名称:WM6183
CUB5IB00 功能描述:DC METER RED/GREEN BKLT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030
CUB5IB00 CALIBRATED 制造商:Red Lion Controls 功能描述:DIGITAL PANEL METER MODEL CUB5 WITH CERTIFICATE OF CALIBRATION
CUB5IR00 功能描述:DC METER REFLECTIVE DISP RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030
CUB5OEMS 制造商:Red Lion Controls 功能描述:PROGRAMMING KIT FOR SOFTWARE
CUB5PB00 功能描述:PROCESS METER RED/GREEN BKLT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:* 标准包装:12 系列:* 其它名称:Q7072030